Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Belo Horizonte; s.n; 2016. 85 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-911651

ABSTRACT

A adaptação marginal é um dos requisitos fundamentais para a longevidade e o sucesso das restaurações. O objetivo desse estudo foi avaliar a influência do desajuste interno associado à diferentes agentes cimentantes na desadaptação marginal de coroas em resina nanocerâmica (Lava Ultimate 3M ESPE) confeccionadas pelo sistema CAD-CAM. A partir do escaneamento de um preparo de coroa total em um pré-molar, foram obtidos 36 modelos em metal. Esses foram divididos em seis grupos de acordo com o desajuste interno (70 µm ou 100 µm) e o cimento (Fosfato de zinco- SS White, Cimento de ionômero de vidro- Ketac Cem 3M/ESPE e Cimento resinoso- Relyx Ultimate 3M/ESPE). Após escaneamento de todos os modelos as coroas foram confeccionadas a partir da fresagem de blocos de resina nanocerâmica (Lava Ultimate 3M/ESPE). Com auxílio de microscópio óptico comparador (40X) foram medidas as desadaptações marginais prévia e posteriormente à cimentação, sendo considerados 8 pontos ao longo do término em todas as faces do corpo de prova. Os valores obtidos após serem submetidos aos testes two-way anova e teste t, demonstraram que as coroas confeccionadas com desajuste interno de 70 µm apresentam desadaptação marginal inferior estatisticamente significante às coroas com desajuste interno de 100 µm. Para o desajuste interno de 70 µm o grupo do cimento fosfato de zinco apresentou o menor gap marginal, sendo que este valor não foi estatisticamente diferente em relação ao grupo do Ketac Cem. Ainda com esse desajuste, o grupo do Ketac Cem não apresentou diferença estatística significante em relação ao grupo do Relyx Ultimate, no entanto esse último promoveu "gap" marginal estatisticamente maior em relação ao grupo do cimento fosfato de zinco. Para o desajuste interno de 100 µm não houve diferença estatisticamente significante no "gap" marginal entre os três cimentos avaliados. O presente estudo demonstrou através da metodologia utilizada, que a menor desadaptação marginal observada nas restaurações de Lava Ultimate, foi proveniente do desajuste interno de 70 µm. Neste grupo os cimentos de fosfato de zinco e de ionômero de vidro demonstraram melhor comportamento comparado ao cimento resinoso, embora o cimento de ionômero de vidro numericamente, mas não estatisticamente tenha apresentado resultado inferior ao do fosfato de zinco


The marginal adaptation is one of the basic requirements for the longevity and success of restorations. The aim of this study was to evaluate the influence of the internal imbalances associated with different luting agents on marginal leakage of crowns Nanoceramic resin ( Lava Ultimate 3M ESPE) made by CAD-CAM system. From the scanning of a full crown preparation in a pre molar were obtained 36 metal models. These were divided into six groups according to the internal imbalances ( 70 or 100 micrometres) and cement (SS White Zinc phosphate, glass ionomer cemet Ketac Cem 3M/ Espe and resinous cement Relyx Ultimate 3M / Espe). After scanning all models crowns were made from milling Nanoceramic resin blocks (Lava Ultimate 3M / Espe). With the aid of optical comparator microscope (40X) were measured prior marginal mismatches and after the cementation, being considered 8 points along the end in all specimen faces. The values were submitted to ANOVA two-way test and t test. Results showded that crowns made with internal imbalances of 70 uM show statistically significant lower marginal leakage to the crows with internal imbalances of 100 micrometres. For the internal imbalances 70 uM zinc phosphate cement group showed the lowest "gap" marginal, and this figure does not show a statistically significant difference compared to Ketac Cem gropu. Even with this misfit, Ketac Cem group showed no statistically significant difference in relation to Relyx Ultimate group, though the latter showed a statistically significant difference compared to zinc phosphate cement group. For the internal imbalances of 100 micrometres there was no statistically significant difference in the "gap" marginal among the three cements. This study demostrated through the methodology used, the lower marginal leakage oberved in Lava Ultimate restorations, was from the inner misfit 70 micrometers...


Subject(s)
Computer-Aided Design/statistics & numerical data , Dental Cements/therapeutic use , Dental Marginal Adaptation/classification , Dental Restoration, Permanent/trends , Glass Ionomer Cements/therapeutic use , Metal Ceramic Alloys/analysis , Resin Cements/therapeutic use , Resins, Synthetic/analysis , Zinc Phosphate Cement/therapeutic use , Models, Dental/statistics & numerical data
2.
Belo Horizonte; s.n; 2016. 89 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-912003

ABSTRACT

Objetivou-se, a partir do Método dos Elementos Finitos, avaliar a biomecânica da união dente-implante e implante-implante, além de estabelecer uma análise qualitativa com achados fotoelásticos prévios. Foram planejados quatro modelos tridimensionais: dois Modelos Teste (dentes unidos a implantes) e dois Modelos Controle (a mesma condição, porém implanto suportada). Os implantes (ANKYLOS® - Dentsply) apresentaram conexão cônica, roscas quadradas e pilares Switching. Suas dimensões, ângulos externos e pilares protéticos foram obtidos a partir de um projetor de perfil. Já, dentes e próteses, a partir da visão direta, tiveram suas formas externas construídas em plataforma CAD (SOLIDSWORKS). O suporte alveolar foi configurado como um retângulo (68/30/15 mm). Todos os pilares foram posicionados no suporte alveolar, conforme os modelos físicos pré-existentes, gerando modelos sólidos. O ligamento periodontal consistiu de uma camada de 0,25 mm de espessura em poliéter (Impregum Soft, 3M Espe). Os modelos de dentes foram produzidos em dentina, pilares e implantes em titânio puro, próteses em liga Níquel-Cromo (Ni-Cr), e o suporte alveolar em resina fotoelástica (Araldite® - Produtos Químicos Ciba S/A do Brasil). As propriedades da resina foram obtidas por meio de ensaio de tração. Carga pontual, vertical e estática, de 150 N, foi aplicada. Os resultados destes ensaios evidenciaram menor concentração de tensão no aspecto cervical de implantes do grupo teste. Ao se confrontar tais achados com os fotoelásticos anteriormente obtidos, foi possível estabelecer uma relação direta entre as áreas mais solicitadas para os modelos de prótese fixa (PF) de três elementos. Concluiu-se que, para as condições estudadas ¿ conexão cônica, roscas quadradas e restauração com Plataforma Switching ¿, unir dentes a implantes parece ser uma terapia clínica viável, sugerindo, inclusive, ser mais favorável que a união de implantes entre si. Além disso, a partir da afinidade positiva entre os achados das duas técnicas, pôde-se considerar validados os modelos matemáticos de prótese fixa de três elementos


The goal of this study was to evaluate, from the Finite Element Method, the biomechanics of implant-tooth union and implant-implant and to establish a qualitative analysis with previous photoelastic findings. Four three-dimensional models were planned: two Test Models (teeth attached to implants) and two Control Models (the same condition, however implant supported). The implants (ANKYLOS® - Dentsply) showed conical connection, square threads and Switching pillars. Their dimensions, external angles and abutments were obtained from a profile projector. Already, teeth and dentures, from direct view, had their external forms built in CAD platform (SOLIDSWORKS). Alveolar support wasconfigured as a rectangle (68/30/15 mm). All the pillars were placed in the alveolar support, as the pre-existing physical models, generating solid models. The periodontal ligament consists of a layer of 0.25 mm thick in polyether (Impregum Soft, 3M Espe). The models of teeth trumped up of dentin, abutments and implants of pure titanium, prosthetics of Nickel-Chrome (Ni-Cr) alloy and alveolar support in photoelastic resin (Araldite® - Chemicals Ciba S/A of Brazil). The resin properties were obtained by traction tests. Punctual and vertical static load of 150 N was applied. The results of these tests showed lower concentration of tension in the cervical aspect of the test group implants. When comparing these findings with the photoelastic previously found, it was possible to establish a direct relation between the areas most requested for fixed prosthesis (FP) models of three elements. It was concluded that, for the studied conditions tapered connection, square threads and Platform Switching restoration , joining teeth implants seems to be a viable clinical therapy, suggesting, inclusive, to be more favorable than to join implants each other. Moreover, from the positive affinity between the findings of the two techniques, it was possible to consider validated the mathematical models of fixed prosthesis of three elements


Subject(s)
Dental Implant-Abutment Design/trends , Dental Implantation, Endosseous/adverse effects , Dental Implants/trends , Models, Dental/statistics & numerical data , Dental Prosthesis, Implant-Supported/trends , Finite Element Analysis/statistics & numerical data , Imaging, Three-Dimensional/statistics & numerical data , Periodontal Ligament , Biomechanical Phenomena , Tensile Strength
3.
Rev. ecua-ortod ; (2): 1-8, nov. 1997. ilus
Article in Spanish | LILACS | ID: lil-243488

ABSTRACT

Las anomalías de malposición dentaria se presentan en un porcentaje muy elevado a nivel mundial. En el Ecuador y especialmente en Guayaquil, según observaciones e información de ortodoncistas, se conoce que existe un elevado porcentaje de anomalías que deben ser analizadas e investigadas. Es conocido por quienes hacemos salud bucal y general, que las anomalías dentomaxilofaciales producen trastornos en la masticación, dicción, deglución, A.T.M. y estética facial. Como consecuencia, producen trastornos funcionales y psicológicos que alteran la salud general. Por esta razón, hemos iniciado un estudio descriptivo de las anomalías de malposición dentaria en niños de 7 a 12 años de zonas urbano marginales en seis escuelas y un sector urbano de la ciudad de Guayaquil, durante los años 1993 a 1996


Subject(s)
Humans , Male , Female , Malocclusion/classification , Malocclusion/epidemiology , Cephalometry , Cross-Sectional Studies , Dental Arch/anatomy & histology , Models, Dental/statistics & numerical data , Dentition, Mixed , Epidemiology, Descriptive , Tooth Extraction/statistics & numerical data , Malocclusion, Angle Class I/epidemiology , Malocclusion, Angle Class II/epidemiology , Malocclusion, Angle Class III/epidemiology , Malocclusion/diagnosis , Malocclusion/etiology , Forecasting/methods , Prospective Studies , Radiography, Panoramic , Stratified Sampling
4.
Rev. Hosp. Clin. Univ. Chile ; 8(1): 9-12, mar. 1997. tab
Article in Spanish | LILACS | ID: lil-202639

ABSTRACT

Se realiza un estudio en el cual se hacen mediciones en modelos de pacientes atendidos en la sección de Ortodoncia del Servicio Dental del Hospital José Joaquín Aguirre, con el propósito de comparar estos resultados con los índices actualmente utilizados en la clínica. Las mediciones corresponden al ancho mesiodistal de los incisivos superiores e inferiores y se realiza con un compás de punta metálica y un calibrador. Se analiza el tamaño individual de cada diente, se compara con su homólogo y se analiza el Indice Incisivo. Se entregan los resultados con los análisis y se comparan con los de otros autores extranjeros. Se entregan conclusiones del trabajo


Subject(s)
Humans , Incisor/anatomy & histology , Models, Dental/statistics & numerical data , Tooth/anatomy & histology
5.
Rev. ADM ; 52(6): 293-8, nov.-dic. 1995. ilus
Article in Spanish | LILACS | ID: lil-172587

ABSTRACT

Los estudiantes de odontología pueden educarse en las técnicas quirúrgicas bucales utilizando un modelo adaptado previo al manejo de pacientes reales. Esta práctica es un valioso instrumento para ofrecer una atención quirúrgica segura en el consultorio dental. El modelo que aquí se propone se ha utilizado durante 13 años en la planeación y ejecución de exodoncia complicada, transfiriendo los conceptos del aula a la clínica


Subject(s)
Surgery, Oral/education , Models, Dental/statistics & numerical data , Tooth Extraction/methods , Manikins , Education, Dental, Graduate/methods
6.
Rev. Fac. Odontol. (Córdoba) ; 21/22(1/2): 61-8, ene. 1993-dic. 1994. ilus
Article in Spanish | LILACS | ID: lil-197188

ABSTRACT

El adiestramiento preclínico previo a la enseñanza de la endodoncia, está reconocido y aceptado por la mayoría de las facultades y escuelas de odontología del mundo. Su desarrollo exige disponer de espacio, tiempo y aparatología suficientes, lo que crea un verdaero problema cuando la población estudiantil es numerosa. Se describen una serie de dispositivos utilizados como auxiliares didácticos, especialmente para las tomas radiográficas, en la Cátedra de Endodoncia "B" de la Facultad de Odontología de la Universidad Nacional de Córdoba (Argentina), que van desde el clásico maniquí que permite la toma de una sola radiografía por disparo y de un dispositivo que hace posible la toma de 4 a 8 radiografías simultaneamente. Los mismos permiten ventajas tales como: 1) obtener placa de buena definición y escasa distorsión, 2) economizar tiempo, 3) aprovechar al máximo las exposiciones radiográficas con el mínimo desgaste de la aparatología, ya que el número de disparos puede reducirse a una cuarta u octava parte


Subject(s)
Education, Dental/methods , Endodontics/education , Schools, Dental/trends , Models, Dental/statistics & numerical data , Radiography, Dental/instrumentation , Radiography, Dental/methods
7.
Egyptian Orthopaedic Journal [The]. 1992; 6 (2): 1-11
in English | IMEMR | ID: emr-23807
SELECTION OF CITATIONS
SEARCH DETAIL